====== Commissioning ====== ===== Control system ===== HEMS controller [[en:hiq_hw:hc-iq-hems|HC-IQ-HEMS]] and all communication interfaces are supplied with preinstalled firmware. For system configuration use [[en:goflex_hems:software|HIQ HEMS Configurator]] . ===== Power meters ===== - **Connect** only **one new power meter** at the time. - In **HIQ HEMS Configurator** go to **settings** page. New power-meter should be detected (Address and Type should be displayed). - Long-press button on power meter until **-SET-** is displayed. - Press **New address** and enter new address according to following table. |<20% 60% >| ^ Device ^ Address | | Grid | 150 | | || | 1st power plant | 154 | | 2nd power plant | 155 | | 3rd power plant | 156 | | || | 1st storage | 157 | | 2nd storage | 158 | | || | 1st consumer | 160 | | 2nd consumer | 161 | | ... | ... | | 8th consumer | 167 | ===== Load managers ===== ==== Add new device ==== - In **HIQ HEMS Configurator** go to **wireless** page - **Click on device** which will be added - Wait for **network open - waiting device** status. - Press **button on device**. - Wait until device is addressed and configured. Procedure can be interrupted with "**close network**" button. ==== Remove device ==== - **Reset device**: * power off wireless device for a few seconds. * After powering on wait for a few seconds for device to boot on. * Press and hold button, LED indicator will go **off**, then **green** and at the end **red**. * Release button. - In **HIQ HEMS Configurator** go to **wireless** page - Reset device should have error state (yellow sign with exclamation) - Click on reset device to clear place. ===== Control devices ===== - In **HIQ HEMS Configurator** go to **wireless** page - **Press icon** for control device (wireless enocean push-button) to be configured - On control device **press 0** (off) button - On control device **press 1** (on) button ===== Sensors ===== ==== Add new sensor ==== - Adjust sensor address with **DIP-switches** according following table - In **HIQ HEMS Configurator** click on sensor which will be added - Wait for **network open - waiting device** status - **Power on** and **pres button** on sensor - Wait until sensor is configured Procedure can be interrupted with **“close network”** button. |< 25% 25% 25% >| ^ Sensor ^ Address ^ DIP switch settings | | S1 | 60 | {{ hiq_energy:goflex_hems:methods_resources:addr_60.png?nolink&100 |}} | | S2 | 61 | {{ hiq_energy:goflex_hems:methods_resources:addr_61.png?nolink&100 |}} | | S3 | 62 | {{ hiq_energy:goflex_hems:methods_resources:addr_62.png?nolink&100 |}} | | S4 | 63 | {{ hiq_energy:goflex_hems:methods_resources:addr_63.png?nolink&100 |}} | | S5 | 64 | {{ hiq_energy:goflex_hems:methods_resources:addr_64.png?nolink&100 |}} | | S6 | 65 | {{ hiq_energy:goflex_hems:methods_resources:addr_65.png?nolink&100 |}} | | S7 | 66 | {{ hiq_energy:goflex_hems:methods_resources:addr_66.png?nolink&100 |}} | | S8 | 67 | {{ hiq_energy:goflex_hems:methods_resources:addr_67.png?nolink&100 |}} | ==== Remove sensor ==== - **Reset sensor**: * Power off sensor for few seconds * Reconnect sensor power supply * After sensor power on (but within 20 sec) press and hold button for at least 6 sec - In **HIQ HEMS Configurator** reset device should show error - **Click** on error icon **to free** occupied space