-====== HEMS v1.2.Configurator ======+====== HEMS v1.2.Configurator ======
  
-{{ :hiq_energy:hems_v1_2_0::hems_configurator_v1.2.0.exe|HEMS Configurator}}+{{ :hiq_energy:hems_v1_2_0::hems_configurator_v1.2.2.exe|HEMS Configurator}}
  
 ===== home ===== ===== home =====
Line 366: Line 366:
 | :::                  | [detect]   | HIQ Home address is cleared so new can be detected.                                                                                         | | :::                  | [detect]   | HIQ Home address is cleared so new can be detected.                                                                                         |
 |  Virtual grid PM     | [] enable  | Check if system is without main grid power meter. Energy, power and currents are calculated from other power meters.                        | |  Virtual grid PM     | [] enable  | Check if system is without main grid power meter. Energy, power and currents are calculated from other power meters.                        |
-^ 2. Internet access and modbus                                                                                                                                                 ||| +^ 2. Modbus cycle time                                                                                                                                                 |||
-|  [] enable           | When checked HEMS is automatically connected to HIQ Universe cloud service. The connection is initialized by the HEMS system and uses UDP packets on port 8442. || +
-|  [test]              | New "push" message is sent to server and roundtrip time is rechecked.                                                                                   || +
-|  [reset]             | Clear messages counts and roundtrip time                                                                                                                || +
-|  push timer          | Timer in s for send "push" message to server                                                                                                            || +
-|  messages            | Sent "push" messages / responses counters                                                                                                               || +
-|  roundtrip           | Time in ms between sent push message and response.                                                                                                      ||+
 |  Modbus cycle time   | Time in ms for modbus communication to complete reading of all connected devices.                                                                       || |  Modbus cycle time   | Time in ms for modbus communication to complete reading of all connected devices.                                                                       ||
 ^ 3. Sources and Consumers settings table                                                                                                                                       ||| ^ 3. Sources and Consumers settings table                                                                                                                                       |||