User Tools

Site Tools


en:ms_main:wiring

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Last revisionBoth sides next revision
en:ms_main:wiring [2020/11/15 16:42] marjan_strnaden:ms_main:wiring [2020/11/15 16:46] marjan_strnad
Line 8: Line 8:
 Individual lights (or hard-wired light groups) are wired directly to the distribution box with an appropriate wire gauge (usually 3 × 1,5 mm<sup>2</sup>). Individual lights (or hard-wired light groups) are wired directly to the distribution box with an appropriate wire gauge (usually 3 × 1,5 mm<sup>2</sup>).
  
-Push-button flush boxes are wired:+===== Push-button flush boxes are wired: =====
 - directly to the distribution box with signal wires. One wire for each push-button and one common wire (for 3 push-buttons: 4 × 0,5 mm<sup>2</sup>). Push buttons that are controlling same light are connected to the same input in parallel - directly to the distribution box with signal wires. One wire for each push-button and one common wire (for 3 push-buttons: 4 × 0,5 mm<sup>2</sup>). Push buttons that are controlling same light are connected to the same input in parallel
 +
 - directly to the distribution box with Cat5+ cable. Up to four buttons on one Cat5+ cable. One core wire for each push-button and one twisted pair for common (for 4 push-buttons: Cat 5+<sup>2</sup>). Push buttons that are controlling same light are connected to the same input in parallel. - directly to the distribution box with Cat5+ cable. Up to four buttons on one Cat5+ cable. One core wire for each push-button and one twisted pair for common (for 4 push-buttons: Cat 5+<sup>2</sup>). Push buttons that are controlling same light are connected to the same input in parallel.
  
-Motion sensors are wired:+====== Motion sensors are wired: ======
 - directly to the distribution box with signal wires. One wire for each sensor and one common wire (for 3 push-buttons: 4 × 0,5 mm<sup>2</sup>). Sensors that are controlling same light are connected to the same input in parallel. - directly to the distribution box with signal wires. One wire for each sensor and one common wire (for 3 push-buttons: 4 × 0,5 mm<sup>2</sup>). Sensors that are controlling same light are connected to the same input in parallel.
 +
 - directly to the distribution box with Cat5+ cable. Up to four sensors on one Cat5+ cable. One core wire for each sensor, one twisted pair for +24 VDC power supply and one twisted pair for 0 VDC (ground) power supply  (for 4 sensors: Cat 5+<sup>2</sup>). Sensors that are controlling same light are connected to the same input in parallel. - directly to the distribution box with Cat5+ cable. Up to four sensors on one Cat5+ cable. One core wire for each sensor, one twisted pair for +24 VDC power supply and one twisted pair for 0 VDC (ground) power supply  (for 4 sensors: Cat 5+<sup>2</sup>). Sensors that are controlling same light are connected to the same input in parallel.
 More sensors can be used for the same light. More sensors can be used for the same light.
en/ms_main/wiring.txt · Last modified: 2020/11/15 16:47 by marjan_strnad