Line 8: Line 8:
 Individual lights (or hard-wired light groups) are wired directly to the distribution box with an appropriate wire gauge (usually 3 × 1,5 mm<sup>2</sup>). Individual lights (or hard-wired light groups) are wired directly to the distribution box with an appropriate wire gauge (usually 3 × 1,5 mm<sup>2</sup>).
  
-Push-button flush boxes are wired: +===== Push-button flush boxes are wired: =====
 - directly to the distribution box with signal wires. One wire for each push-button and one common wire (for 3 push-buttons: 4 × 0,5 mm<sup>2</sup>). Push buttons that are controlling same light are connected to the same input in parallel - directly to the distribution box with signal wires. One wire for each push-button and one common wire (for 3 push-buttons: 4 × 0,5 mm<sup>2</sup>). Push buttons that are controlling same light are connected to the same input in parallel
  
 - directly to the distribution box with Cat5+ cable. Up to four buttons on one Cat5+ cable. One core wire for each push-button and one twisted pair for common (for 4 push-buttons: Cat 5+<sup>2</sup>). Push buttons that are controlling same light are connected to the same input in parallel. - directly to the distribution box with Cat5+ cable. Up to four buttons on one Cat5+ cable. One core wire for each push-button and one twisted pair for common (for 4 push-buttons: Cat 5+<sup>2</sup>). Push buttons that are controlling same light are connected to the same input in parallel.
  
-Motion sensors are wired: +===== Motion sensors are wired: =====
 - directly to the distribution box with signal wires. One wire for each sensor and one common wire (for 3 push-buttons: 4 × 0,5 mm<sup>2</sup>). Sensors that are controlling same light are connected to the same input in parallel. - directly to the distribution box with signal wires. One wire for each sensor and one common wire (for 3 push-buttons: 4 × 0,5 mm<sup>2</sup>). Sensors that are controlling same light are connected to the same input in parallel.
  