en:3s:hw [2020/07/20 10:48] – created vidben:3s:hw [2020/08/10 07:46] (current) – [Wiring] goran.kocjancic
Line 1: Line 1:
 ====== HARDWARE ====== ====== HARDWARE ======
  
-SafeGate's hardware includes QR code and RFID card reader, TOF sensor, body temperature sensor and protective mask detector.+SafeGate's hardware includes QR code and RFID card reader, TOF sensor, body temperature sensor and protective mask detector. The last two can be combined into face scanner. 
 + 
 +===== Wiring ===== 
 + 
 +^ Device                        ^  Power supply      Conected to               || 
 +| TOF sensor                    | POE                MC     | GND, IX0, IX1     | 
 +| Temperature and mask scanner  | PS: 12 VDC        |  MC     | GND, IX2          | 
 +| QR and RFID reader            | CR-W2: +12V, GND  |  CR-W2  | D0, D1-0, GN-0    | 
 +| Entrance allowed              | -                  CR-W2  | C0 - QX0 (Relay) 
 +| REED entrance                 | -                  CR-W2  | GND - IW0         | 
 +| Button entrance               | -                  CR-W2  | GND - IW1         | 
 +| Exit allowed                  | -                  CR-W2  | C0 - QX1 (Relay) 
 +| REED exit                     | -                  CR-W2  | GND - IW2         | 
 +| Button exit                   | -                  CR-W2  | GND - IW3         | 
 +| Motion sensor                 | MC: +24V, GND      MC     | IO12              | 
 +| Hand disinfection             | EXT:              |  MC     | GND - IO15        | 
 +| Alarm                         | PS: 12 VDC        |  MC     | C1 - QX2 (Relay) 
 +| LED Display                   | EXT: 230 VAC      |  MC     | TxD, RxD, GND     | 