Previous revision
en:hems:methods_resources:commissioning [2020/08/13 13:57] amra.begicen:hems:methods_resources:commissioning [2021/02/02 10:50] (current) – [Configuration] saso_santelj
Line 8: Line 8:
  
  
-Wire all elements **except** communication with single-phase **PM1-E-D sensors**.+Wire all elements **except** communication with **PM1-E-D** and **PM3-E-D sensors**.
  
 Connect the MC-230 to the home LAN. Connect the MC-230 to the home LAN.
Line 15: Line 15:
  
  
-Install and run {{ :hiq_energy:hems:methods_resources:hems_configurator_v1.1.1.exe|HEMS Configurator}} on your PC.+Install and run {{ :hiq_energy:hems:methods_resources:hems_configurator_v1.1.2.exe|HEMS Configurator}} on your PC.
  
 Go to the "**settings**" page. Go to the "**settings**" page.
Line 91: Line 91:
   * To confirm that the pairing is OK, the LED will blink in green   * To confirm that the pairing is OK, the LED will blink in green
   * In the HEMS Configurator module should appear as "new device"   * In the HEMS Configurator module should appear as "new device"
-  * Click on the **" add"** button next to the consumer that connected to the module+  * Click on the **" add"** button next to the consumer that is connected to the module
  
 == Relay switch-1 channel== == Relay switch-1 channel==
Line 98: Line 98:
   * To confirm that the pairing is OK, the LED will blink green twice   * To confirm that the pairing is OK, the LED will blink green twice
   * The HEMS Configurator module should appear as a "new device"   * The HEMS Configurator module should appear as a "new device"
-  * Click on the **" add"** button next to the consumer that connected to the module+  * Click on the **" add"** button next to the consumer that is connected to the module
  
 == Relay switch-2 channel== == Relay switch-2 channel==
Line 105: Line 105:
   * To confirm that the pairing is OK, the LED will blink green twice   * To confirm that the pairing is OK, the LED will blink green twice
   * In the HEMS Configurator the module first channel should appear as a "new device"   * In the HEMS Configurator the module first channel should appear as a "new device"
-  * Click on the **" add"** button next to the consumer that connected to the module first channel+  * Click on the **" add"** button next to the consumer that is connected to the modules first channel
   * In the HEMS Configurator the module second channel should appear as a "new device"    * In the HEMS Configurator the module second channel should appear as a "new device" 
-  * Click on the **" add"** button next to the consumer that connected to the module second channel+  * Click on the **" add"** button next to the consumer that is connected to the modules second channel
   * Before you pair a new device both channels must be added to the consumers   * Before you pair a new device both channels must be added to the consumers
  
Line 115: Line 115:
  
   * In the HEMS Configurator press **"del"** button next to the consumer connected to the module you want to remove   * In the HEMS Configurator press **"del"** button next to the consumer connected to the module you want to remove
-  * After a few secondsthe module is removing+  * After a few seconds the module is removed
  
 == Relay switch-2 channel== == Relay switch-2 channel==
  
   * In the HEMS Configurator press **"del"** button next to the consumer connected to the channel module you want to remove   * In the HEMS Configurator press **"del"** button next to the consumer connected to the channel module you want to remove
-  * After a few seconds, delete the channel of a module should appear as the "new device" +  * After a few seconds, deleted channel of a module should appear as "new device" 
-  * If desired, the module can be removing if delete another channel or the deleted channel can be assigned to another consumer+  * We can remove the module by deleting the second channel or the deleted channel can be assigned to another consumer
  
 === Setting repeater level === === Setting repeater level ===
-When enabling repeater mode, the wireless module can repeater a message not addressed to him, and increase range by creating network gride between all wireless devices.+When enabling repeater mode, the wireless module can repeat a message not addressed to him, and increase range by creating network grid between all wireless devices.
  
 The repeater can be configured to level 0 (off), level 1 (one hop), or level 2 (two hops): The repeater can be configured to level 0 (off), level 1 (one hop), or level 2 (two hops):
Line 168: Line 168:
 ==== Backup / restore to PC ==== ==== Backup / restore to PC ====
  
-HEMS Configurator allows you to backup and restores all parameters to pc.+HEMS Configurator allows you to backup and restores all parameters to PC.
  
 ¹ Only for the first power plant ¹ Only for the first power plant
en/hems/methods_resources/commissioning.1597327023.txt.gz · Last modified: 2020/08/13 13:57 by amra.begic