User Tools

Site Tools


en:hems:methods_resources:commissioning

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en:hems:methods_resources:commissioning [2021/01/31 18:50] – [Micro smart plug, smart plug and relay switch-1 channel] saso_santeljen:hems:methods_resources:commissioning [2021/02/02 10:50] (current) – [Configuration] saso_santelj
Line 15: Line 15:
  
  
-Install and run {{ :hiq_energy:hems:methods_resources:hems_configurator_v1.1.1.exe|HEMS Configurator}} on your PC.+Install and run {{ :hiq_energy:hems:methods_resources:hems_configurator_v1.1.2.exe|HEMS Configurator}} on your PC.
  
 Go to the "**settings**" page. Go to the "**settings**" page.
Line 120: Line 120:
  
   * In the HEMS Configurator press **"del"** button next to the consumer connected to the channel module you want to remove   * In the HEMS Configurator press **"del"** button next to the consumer connected to the channel module you want to remove
-  * After a few seconds, delete the channel of a module should appear as the "new device" +  * After a few seconds, deleted channel of a module should appear as "new device" 
-  * If desired, the module can be removing if delete another channel or the deleted channel can be assigned to another consumer+  * We can remove the module by deleting the second channel or the deleted channel can be assigned to another consumer
  
 === Setting repeater level === === Setting repeater level ===
-When enabling repeater mode, the wireless module can repeater a message not addressed to him, and increase range by creating network gride between all wireless devices.+When enabling repeater mode, the wireless module can repeat a message not addressed to him, and increase range by creating network grid between all wireless devices.
  
 The repeater can be configured to level 0 (off), level 1 (one hop), or level 2 (two hops): The repeater can be configured to level 0 (off), level 1 (one hop), or level 2 (two hops):
Line 168: Line 168:
 ==== Backup / restore to PC ==== ==== Backup / restore to PC ====
  
-HEMS Configurator allows you to backup and restores all parameters to pc.+HEMS Configurator allows you to backup and restores all parameters to PC.
  
 ¹ Only for the first power plant ¹ Only for the first power plant
en/hems/methods_resources/commissioning.1612119018.txt.gz · Last modified: 2021/01/31 18:50 by saso_santelj