Line 1: Line 1:
-===== Application Programming Interface (API) ===== 
- 
-==== Direct loads control ==== 
- 
-| ''load_set[i]''   | bit | R/W | Managed load state; 0=off, 1=on; i = 10..17 | 
-| ''analog_out[i]'' | int | R/W | Analog output value in % i = 10..13         | 
- 
-==== Timetable ==== 
- 
-|< 70% 25% 3% 3% >| 
-| ''timetable_cloud_once[i]''            |  bit  |  RO  | Enabled cloud optimization for "once" actions; 0=disabled, 1=enabled; i=0..7                | 
-| ''timetable_cloud_recurring[i]''        bit  |  RO  | Enabled cloud optimization for "recurring" actions; 0=disabled, 1=enabled; i=0..7           | 
-| ''timetable_analog_optimization[i]''    bit  |  RO  | Enabled cloud optimization for analog timetable; 0=disabled, 1=enabled; i=0..3              | 
- 
-|< 70% 25% 3% 3% >| 
-| ''optimization_index[i]''              |  int  |  RW  | Timetable optimization index (0=broadcast = all timetables); i=0..50                                 | 
-| ''optimization_start[i]''              |  int  |  RW  | Timetable optimization start time; hhmmw; hh=hour, mm=minute, w=weekday(1=monday); i=0..50           | 
-| ''optimization_time[i]''                int  |  RW  | Timetable optimization period in min; i=0..50                                                        | 
-| ''optimization_command[i]''            |  int  |  RW  | Timetable optimization command, auto set to 0 after being processed  - see following table; i=0..50  
-| ''optimization_value[i]''              |  int  |  RW  | Timetable optimization value , depends of ''optimization_command'' - see following table; i=0..50    | 
- 
-<wrap hi> Variable ''optimization_command'' triggers timetable manipulation process so make sure to set all other variables before. </wrap> 
- 
-|< 70% 3% 47% 3% >| 
-|       ''optimization_command''           ||        ''optimization_value''                    || 
-|  1  | **managed load once actions**               | Set **OFF**                           | 
-| ::: | :::                                         | Set **ON**                            | 
-| ::: | :::                                  -1       | **Delete**                            | 
-|  2  | **managed load recurring actions**  |         | Set **OFF**                           | 
-| ::: | :::                                         | Set **ON**                            | 
-| ::: | :::                                  -1       | **Delete**                            | 
-|  3  | **tariff timetable**                |         | Set **LO**                            | 
-| ::: | :::                                         | Set **HI**                            | 
-| ::: | :::                                         | Set **DYNAMIC**                       | 
-| ::: | :::                                  -1       | **Delete** Dynamic                    | 
-|  4  | **set mask**                        |   0..0xFF | Set once **on/off** as per bit value  | 
-|  5  | **analog timetable**                |   0..100  | Set **0..100%**                       | 
-| ::: | :::                                  -1       | **Delete** Analog                     | 
-|  6  | **battery setpoint**                |   -100..0 | Set discharge **0..100%**             | 
-| ::: | :::                                  0..100   | Set charge **0..100%**                | 
-| ::: | :::                                  -31768   | Set **auto**                          | 
- 
  
en/hems/universe/api.1538984177.txt.gz · Last modified: 2018/10/08 07:36 by goran.kocjancic