* After a few seconds, the sensor should appear as the "new device" | * After a few seconds, the sensor should appear as the "new device" | ||
* If desired, the sensor can be removed or it can be assigned to another device | * If desired, the sensor can be removed or it can be assigned to another device | ||
+ | <WRAP pagebreak></ | ||
==== Power plant connection ==== | ==== Power plant connection ==== | ||
Line 174: | Line 174: | ||
HEMS is supporting up to 8 digital outputs on MC controller (QX0, | HEMS is supporting up to 8 digital outputs on MC controller (QX0, | ||
- | * using HEMS configurator on settings page, define | + | * using [[en: |
* on IO MUX page assign digital to output port (e.g. IO15 -> Digital 2): in this case consumer 2 (Digital-2) is assigned to IO15 port and enables ON/OFF functionality on it. | * on IO MUX page assign digital to output port (e.g. IO15 -> Digital 2): in this case consumer 2 (Digital-2) is assigned to IO15 port and enables ON/OFF functionality on it. | ||
- | **Note**: if it is set Digital | + | **Note**: if it is set **digital** |
==== Analog output ==== | ==== Analog output ==== | ||
- | HEMS is supporting up to 8 digital outputs on MC controller (QX0, | + | On port IO14 is supported analog output 0-10V, while on IO15 is PWM signal with frequency of 1kHz. Using analog load is possible for consumer 1 only! How to set ([[en: |
- | * using HEMS configurator on settings page, define | + | * using [[en: |
- | * on IO MUX page assign digital to output | + | * on IO MUX page define IO14 and/or IO15 port for Analog/PWM output, |
+ | * on home screen define analog value 0-100% | ||
+ | |||
+ | **Note**: if it is set **analog** for consumer without assigned power sensor, it is possible to define **P nominal** power instead. It represents fixed power of consumer and while in operating mode HEMS calculates consumed energy. | ||
+ | |||
+ | ==== IO mux ==== | ||
+ | |||
+ | IO mux page within [[en: | ||
+ | * e.g. if it is set QX2 -> Router reset, it means that when conditions are met (for reset), QX2 port will change state to turn OFF router, | ||
+ | * or if it is set QX2 -> Digital-2, it means that digital2 (consumer | ||
+ | * for input ports IX0,IX1 and IX2 it is possible to set toggle and enable functionality ([[en: | ||
- | **Note**: if it is set Digital for consumer without assigned power sensor, it is possible to define **P nominal** power instead. It represents fixed power of consumer and while in operating mode HEMS calculates consumed energy. | ||
==== Permanent memory ==== | ==== Permanent memory ==== |