Line 70: Line 70:
   * After a few seconds, the sensor should appear as the "new device"   * After a few seconds, the sensor should appear as the "new device"
   * If desired, the sensor can be removed or it can be assigned to another device   * If desired, the sensor can be removed or it can be assigned to another device
 +<WRAP pagebreak></WRAP>
 ==== Power plant connection ==== ==== Power plant connection ====
  
Line 174: Line 174:
  
 HEMS is supporting up to 8 digital outputs on MC controller (QX0,QX1,QX2,QX3,IO12,IO13,IO14 and IO15). How to set?  HEMS is supporting up to 8 digital outputs on MC controller (QX0,QX1,QX2,QX3,IO12,IO13,IO14 and IO15). How to set? 
-  * using HEMS configurator on settings page, define Digital output for desired consumer (e.g. Digital-2), +  * using [[en:hems_v1_2_0:software|HEMS configurator]] on settings page, define digital output for desired consumer (e.g. Digital-2), 
   * on IO MUX page assign digital to output port (e.g. IO15 -> Digital 2): in this case consumer 2 (Digital-2) is assigned to IO15 port and enables ON/OFF functionality on it.    * on IO MUX page assign digital to output port (e.g. IO15 -> Digital 2): in this case consumer 2 (Digital-2) is assigned to IO15 port and enables ON/OFF functionality on it. 
  
-**Note**: if it is set Digital for consumer without assigned power sensor, it is possible to define **P nominal** power instead. It represents fixed power of consumer and while in operating mode HEMS calculates consumed energy. +**Note**: if it is set **digital** for consumer without assigned power sensor, it is possible to define **P nominal** power instead. It represents fixed power of consumer and while in operating mode HEMS calculates consumed energy. 
  
 ==== Analog output ==== ==== Analog output ====
  
 On port IO14 is supported analog output 0-10V, while on IO15 is PWM signal with frequency of 1kHz. Using analog load is possible for consumer 1 only! How to set ([[en:hems_v1_2_0:wiring|HEMS wiring]])?   On port IO14 is supported analog output 0-10V, while on IO15 is PWM signal with frequency of 1kHz. Using analog load is possible for consumer 1 only! How to set ([[en:hems_v1_2_0:wiring|HEMS wiring]])?  
-  * using HEMS configurator on settings page, define analog output for consumer 1, +  * using [[en:hems_v1_2_0:software|HEMS configurator]] on settings page, define analog output for consumer 1, 
   * on IO MUX page define IO14 and/or IO15 port for Analog/PWM output,   * on IO MUX page define IO14 and/or IO15 port for Analog/PWM output,
-  * . +  * on home screen define analog value 0-100% (long-press) for consumer1 and turn it ON/OFF with short-press 
 + 
 +**Note**: if it is set **analog** for consumer without assigned power sensor, it is possible to define **P nominal** power instead. It represents fixed power of consumer and while in operating mode HEMS calculates consumed energy.  
 + 
 +==== IO mux ==== 
 + 
 +IO mux page within [[en:hems_v1_2_0:software|HEMS configurator]] allows setting of input/output types for ports on controller:  
 +  * e.g. if it is set QX2 -> Router reset, it means that when conditions are met (for reset), QX2 port will change state to turn OFF router, 
 +  * or if it is set QX2 -> Digital-2, it means that digital2 (consumer 2) is assigned to QX2 and enables switching ON/OFF on it, 
 +  * for input ports IX0,IX1 and IX2 it is possible to set toggle and enable functionality ([[en:hems_v1_2_0:wiring|HEMS wiring]]). it means that dedicated consumer will be directly managed (ON/OFF) by input signal on IX0,IX1 or IX2. 
  
-**Note**: if it is set Digital for consumer without assigned power sensor, it is possible to define **P nominal** power instead. It represents fixed power of consumer and while in operating mode HEMS calculates consumed energy.  
  
 ==== Permanent memory ==== ==== Permanent memory ====
en/hems_v1_2_0/commissioning.1637145897.txt.gz · Last modified: 2021/11/17 10:44 by gdzampo