en:hems_v1_2_0:introduction
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| en:hems_v1_2_0:introduction [2021/10/19 07:31] – neoxy | en:hems_v1_2_0:introduction [2021/11/22 12:59] (current) – saso_santelj | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== HEMS v1.2.x Introduction ====== | ====== HEMS v1.2.x Introduction ====== | ||
| + | |||
| Home Energy Management System (HEMS) is a system for: | Home Energy Management System (HEMS) is a system for: | ||
| - | * monitoring electricity flows at home (consumption, | + | * monitoring electricity flows at home (consumption, |
| - | * control of key consumers, | + | * control of key consumers |
| - | * optimizing consumption in terms of reducing consumption and using cheaper energy to ensure the same comfort with lower costs, | + | * optimizing consumption in terms of reducing consumption and using cheaper energy to ensure the same comfort with lower costs |
| - | * current limiting | + | * maximize in-house consumption |
| - | * managing | + | * minimize cost of electrical energy |
| + | * contribute | ||
| + | * provide relevant information and help understanding energy flow | ||
| + | * control and manage devices (producers, consumers, prosumers) | ||
| + | * get access to flexibility trade and other digital services | ||
| + | * manage | ||
| + | * protect main fuse(s) from overcurrent | ||
| + | | ||
| + | | ||
| {{: | {{: | ||
| + | | ||
| + | | ||
| + | | ||
| + | HEMS consists of two parts, one is hardware installed at physical object while second is software to support above listed tasks. Hardware consists of HEMS master controller | ||
| + | and units to be connected on it. Units can be divided on input and output: | ||
| + | * from **input**, controller gets measured values e.g. from different sensors (power sensor-PS, temperature) or ON/OFF signals from thermostat, switches, push buttons, while | ||
| + | * on **output**, controller applies result of control algorithm e.g. with power relays switches ON/OFF devices (water heater, heat pump, washing machine...) or set charging current for EV on charging station or set charge/ | ||
| - | ===== HEMS Controller ===== | + | **HEMS supports**: |
| - | + | ✔ 1 grid power sensor | |
| - | It consists of an HEMS master controller | + | ✔ up to 3 local power plants |
| - | + | ✔ up to 2 local storage systems (home battery) | |
| - | <WRAP pagebreak></ | + | ✔ up to 8 devices (electrical heating, EV charging station, electrical domestic water heater, washing machine, tumble dryer, …) as CONSUMERS. |
| - | + | ||
| - | ===== Temperature sensor ===== | + | |
| - | Temperature sensor is directly wired ([[en: | + | In terms of HEMS terminology there are devices producing energy |
| + | | ||
| + | | ||
| + | - Managed device connected | ||
| + | | ||
| - | ===== Power sensors ===== | + | For connection to cloud HEMS is using IOT linker device. |
| - | The measurement of electrical power and energy of all energy sources and main electrical consumers | + | Below is illustrated |
| - | | + | |
| - | * up to **3** sensors for local power **plants** (PV, Wind, Cogeneration, | + | |
| - | | + | |
| - | * up to **8** managed **consumers** (electrical heating, EV charging station, electrical domestic water heater, washing machine, tumble dryer, ...) | + | |
| - | The measurement of main electrical consumers is also possible with wireless modules ([[en:hiq_hw:en-p1-iq|Metering smart plug]] and [[en:hiq_hw: | + | {{:hiq_energy:hems_v1_2_0:HEMS_intro.png? |
| - | ===== Power relays ===== | + | |
| - | Are used for control of managed consumers. | + | where: |
| + | * temperature sensor is directly wired ([[en: | ||
| + | * measurement of electrical power and energy is provided by single-phase ([[en: | ||
| + | * there are also wireless modules [[en: | ||
| + | * power relays are used for control of managed consumers. | ||
| + | * push button are used for manual control of managed devices and are directly wired to HEMS master controller. | ||
| - | ===== Push buttons ===== | ||
| - | Are used for manual control of managed devices. Push buttons are directly wired or paired ([[en: | ||
| - | {{: | ||
| - | ===== EV chargers ===== | ||
| - | Are used for charging electric vehicles. They are controlled from HEMS master controller [[en: | ||
en/hems_v1_2_0/introduction.1634628673.txt.gz · Last modified: by neoxy