en:hems_v1_2_0:wiring [2021/11/12 08:33] – created saso_santeljen:hems_v1_2_0:wiring [2022/12/09 11:31] (current) saso_santelj
Line 15: Line 15:
  
 |< 700px >| |< 700px >|
-^ Network (LAN or LTE 4G modem) -> MC-230 and IOT-L2-2 \\ Optionally: \\  - PC with HEMS configurator \\  - PV inverter \\   - Hybrid inverter (battery storage system)   \\     - EV charger       +^ Network (LAN or LTE 4G modem) -> MC-230 and IOT-L2-2 \\ Optionally: \\  - PC with HEMS configurator \\  - PV inverter \\   - Hybrid inverter (battery storage system)   \\     - EV charger \\  \\ NOTE: When you change network configuration, MC-230 and IOT-L2-2 must be reset.      
-|Default connection to the LAN:                              |+|Default connection to the LAN network                    |
 |  {{ :hiq_energy:hems_v1_2_0:hems-linker01.png?direct |}}  | |  {{ :hiq_energy:hems_v1_2_0:hems-linker01.png?direct |}}  |
 |Optional LAN connections:                              | |Optional LAN connections:                              |
 |  {{ :hiq_energy:hems_v1_2_0:hems-linker02.png?direct |}}  | |  {{ :hiq_energy:hems_v1_2_0:hems-linker02.png?direct |}}  |
-|  {{ :hiq_energy:hems_v1_2_0:hems-linker03.png?direct |}}  | +<WRAP pagebreak></WRAP> 
-| | +|< 700px >
-| | +| Default connection via LTE 4G modem:                            |
-|Default connection via LTE 4G modem:                            |+
 |**NOTE:** All connected devices will have internet access via LTE modem which can result in high costs on your LTE account. | |**NOTE:** All connected devices will have internet access via LTE modem which can result in high costs on your LTE account. |
 |  {{ :hiq_energy:hems_v1_2_0:hems-linker11.png?direct |}}  | |  {{ :hiq_energy:hems_v1_2_0:hems-linker11.png?direct |}}  |
Line 30: Line 29:
 | | | |
 |**NOTE:** Specific network requirements, i.e. static IP address can be configured on the cloud service. Please contact [[http://support.robotina.com|support]]. | |**NOTE:** Specific network requirements, i.e. static IP address can be configured on the cloud service. Please contact [[http://support.robotina.com|support]]. |
- 
  
 <WRAP pagebreak></WRAP> <WRAP pagebreak></WRAP>
Line 37: Line 35:
 ^ PM3-I-D                                                       | ^ PM3-I-D                                                       |
 |  {{ :hiq_energy:hems:hardware:pm3_terminals.png?direct |}}     | |  {{ :hiq_energy:hems:hardware:pm3_terminals.png?direct |}}     |
- 
-<WRAP pagebreak></WRAP> 
  
 |< 700px >| |< 700px >|
Line 49: Line 45:
 ^ PM1-E-D-CT      | ^ PM1-E-D-CT      |
 |  {{ :hiq_energy:hems:hardware:pm1_ct_terminals.png?direct |}}  | |  {{ :hiq_energy:hems:hardware:pm1_ct_terminals.png?direct |}}  |
- 
-<WRAP pagebreak></WRAP> 
  
 |< 700px >| |< 700px >|
Line 61: Line 55:
 ^ WM-1      | ^ WM-1      |
 |  {{ :hiq_energy:hems:hardware:wm1_wiring.png?direct |}}  | |  {{ :hiq_energy:hems:hardware:wm1_wiring.png?direct |}}  |
- 
- 
-<WRAP pagebreak></WRAP> 
  
 |< 700px >| |< 700px >|
Line 75: Line 66:
 |Connect external source to control device, e.g. thermostat signal on IX0 to control temperature by enabling/disabling connected device on QX0.| |Connect external source to control device, e.g. thermostat signal on IX0 to control temperature by enabling/disabling connected device on QX0.|
 |  {{ :hiq_energy:hems:hardware:water_heater_1.png?direct |}}  | |  {{ :hiq_energy:hems:hardware:water_heater_1.png?direct |}}  |
 +
 +<WRAP pagebreak></WRAP>
 +
 +|< 700px >|
 +^ Set analog for consumer 1  |
 +|Connect analog device to IO14 for analog signal 0-10V or to IO15 for PWM signal (f=1kHz). Analog load is possible to set in configurator for consumer 1 only and reserved outputs are on IO14 & IO15.|
 +|  {{ :hiq_energy:hems:hardware:analog_1.png?direct |}}  |
  
en/hems_v1_2_0/wiring.1636705991.txt.gz · Last modified: 2021/11/12 08:33 by saso_santelj