en:robotina_charger:commissioning:pv_inverter
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
en:robotina_charger:commissioning:pv_inverter [2022/12/09 12:16] – [SolarEdge inverter over Modbus TCP] gdzampo | en:robotina_charger:commissioning:pv_inverter [2022/12/09 14:59] (current) – [EVSE and PV inverter connection] gdzampo | ||
---|---|---|---|
Line 15: | Line 15: | ||
Obtaining relevant data from photovoltaic is possible by two ways:\\ | Obtaining relevant data from photovoltaic is possible by two ways:\\ | ||
- | 1. adding power-sensor to measure produced electricity by PV (no connection to interver). How to add power sensor please see [[en: | + | 1. adding power-sensor to measure produced electricity by PV (no connection to interver) |
2. connecting PV inverter by Modbus TCP to EVSE (only for SolarEdge inverters) | 2. connecting PV inverter by Modbus TCP to EVSE (only for SolarEdge inverters) | ||
- | === SolarEdge | + | === EVSE and PV inverter |
|< 700px >| | |< 700px >| | ||
- | ^ EVSE and PV inverter connection | | ||
| {{ : | | {{ : | ||
+ | |||
+ | To add inverter on HEMS configurator: | ||
+ | * on settings page inside source table, select SolarEdge inverter. Please see [[en: | ||
+ | * on io mux page set IP address for inverter. Please see [[en: | ||
To setup Modbus TCP on Inverter using SetApp: | To setup Modbus TCP on Inverter using SetApp: | ||
* | * | ||
* RS485-1 -> Protocol -> SunSpec (Non-SE Logger) | * RS485-1 -> Protocol -> SunSpec (Non-SE Logger) | ||
- | * RS485-1 -> Device ID, and enter the number 1. | + | * RS485-1 -> Device ID, and enter the number 1 |
- | | + | * Modbus TCP and set to Enable |
- | | + | |
- | * | + | |
- | *TCP port is 1502 by default. | + | **Note**:\\ The TCP server idle time is 2 minutes. In order to leave the connection open, the request should be made within 2 minutes.\\ It is important to follow rules above, firstly to set HEMS configurator following Inverter setup due to 2 minutes time frame. |
en/robotina_charger/commissioning/pv_inverter.1670588163.txt.gz · Last modified: 2022/12/09 12:16 by gdzampo