en:robotina_charger:commissioning:pv_inverter
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
en:robotina_charger:commissioning:pv_inverter [2022/12/09 13:55] – [EVSE and PV inverter connection] gdzampo | en:robotina_charger:commissioning:pv_inverter [2022/12/09 14:59] (current) – [EVSE and PV inverter connection] gdzampo | ||
---|---|---|---|
Line 24: | Line 24: | ||
To add inverter on HEMS configurator: | To add inverter on HEMS configurator: | ||
- | * on settings page inside source table, select SolarEdge inverter. [[en: | + | * on settings page inside source table, select SolarEdge inverter. |
- | * on io mux page define | + | * on io mux page set IP address for inverter. |
To setup Modbus TCP on Inverter using SetApp: | To setup Modbus TCP on Inverter using SetApp: | ||
* | * | ||
* RS485-1 -> Protocol -> SunSpec (Non-SE Logger) | * RS485-1 -> Protocol -> SunSpec (Non-SE Logger) | ||
- | * RS485-1 -> Device ID, and enter the number 1. | + | * RS485-1 -> Device ID, and enter the number 1 |
- | | + | * Modbus TCP and set to Enable |
- | | + | |
- | | + | |
- | + | **Note**:\\ The TCP server idle time is 2 minutes. In order to leave the connection open, the request should be made within 2 minutes.\\ It is important to follow rules above, firstly to set HEMS configurator following Inverter setup due to 2 minutes time frame. | |
- | *TCP port is 1502 by default. | + |
en/robotina_charger/commissioning/pv_inverter.1670594124.txt.gz · Last modified: 2022/12/09 13:55 by gdzampo