-====== EVSE - Robotina Charger v2.0.1 ====== 
- 
-Latest version of Robotina Charger (EVSE) can be found under [[en:robotina_charger:download]] map. 
- 
-===== EVSE overview ===== 
-**Note: Blue color presents editable value, white color values are not editable. ** 
-<WRAP column 550px> 
-{{:hiq_energy:robotina_charger:rc_miniscada_gui.png?direct&400|}} 
-</WRAP> 
- 
- 
-<WRAP column 750px> 
-|< 100% 25% 75%>| 
-^ 1. EVSE Name || 
-|Name of EVSE || 
-^ 2. Limiter sign || 
-|{{hiq_energy:hems_v1_2_0:limiter_active.png?direct&20|}} {{hiq_energy:hems_v1_2_0:limiter_inactive.png?direct&20|}} | Yellow status when limiter is enabled and active. Green status when enabled and not active. None if limiter is not set.| 
-^ 3. Data from ongoing charging session|| 
-|**EV charging icon with LED light** | Different LED light colour is presenting charger state, while icon is as button. Short press for enabling/disabling EVSE, long press for priority charging and error delete.| 
-|**State** | EVSE status: Communication error, Unknown, Available, EV not connected, Starting, Charging, EV paused, EVSE paused, EV not connected, Charging ended, Charging fault, Unpausing, Unavailable, No EVSE response, Locked, Stopping.   | 
-|**Phases** - number of used phases while charging| 3 phases, Phase L1, Phase L2, Phase L3, Unknown phase, 2 phases.| 
-|**Power** | Charging power of EV. | 
-|**EVSE max** | Charging current by phase. | 
-|**Max current** | Allowed max charging current. | 
-|**Last session** | Time - duration of charging session, Energy - consumed energy of charging session.| 
-^ 4. error message(s) || 
-| Possible errors are: CP positive voltage, CP negative voltage, RCD sensor trip, Overvoltage, Undervoltage, Charge with ventilation, PS reading error, Current is higher than allowed, RCD sensor malfunction, Internal temperature is too high.\\ **Note**: for resolving errors please see table below.|| 
-^ 5. EVSE settings|| 
-|**Priority charging** | Utilize all available power to charge as fast as possible ignoring economy charging.| 
-|**Locked** | Disable unauthorized use of EVSE, authorization is possible with RFID tags or by cloud application.| 
-|**Allow charging with ventilation** | Allow/deny charging if EV requests ventilation. | 
-|**Disable button** | Disable functionality of button on housing.| 
-|**Turn LED off after 3 minutes of inactivity** | LED light is turned off after 3 minutes. | 
-|**Economy charging** | **Use current**: set desired current for charging.\\ **Charge only at LO tarriff**: charging possible at low tariff only. Note: LO tarriff must be set.\\ **Charge with surplus energy**: //Off//; //Total// - dynamically charge EV and try to keep total power on grid power sensor close to zero; //Only from surplus// - charges only if there is surplus energy on all phases; //All surplus// - charge EV with if surplus is available | 
-|**EVSE works as slave** | EVSE is a slave to master (Modbus TCP communication) EVSE with its serial number-SN. Green tick if communication is OK, red X for lost communication. | 
-|**Limit if connection with master is lost** | In case of lost communication, use max charging current. | 
-^ 6. Event log || 
-|Shows last 10 charging session. || 
-^ 7. RFID and QR || 
-|Add or delete RFID tag or QR code, for managing authorized access to EVSE. || 
-^ 8. Time & date and SW version || 
-|Time and date with software version release. || 
-^ 9. configurator || 
-|Runs [[en:robotina_charger:software#hems_v201_configurator|Configurator]] || 
-^ 10. autodetect || 
-|Click to find EVSE in local network || 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
-===== Error table ===== 
-<WRAP column 950px> 
-Robotina charger recovers error automatically.  
-To delete error by yourself long press button on charger housing or on application. **Charging is stopped while error is active.** **If red light still flashes, please read table bellow.** 
- 
-|<100% 25% 35%>| 
-^ Error ^Possible causes ^ Possible solution ^ 
-|CP positive voltage\\ CP negative voltage |Measured voltage on CP pin is out of range. | Check your charging cable and plug. Reconnect your EV. | 
-|RCD sensor trip                  | DC current leak detected. | Please contact an authorized car service department. | 
-|RCD sensor malfunction           | RCD sensor is damaged or not connected. | Please contact the service department of your EVSE supplier. | 
-|Undervoltage\\ Overvoltage       | Supply voltage is out of range.  | Please contact  EVSE installer. | 
-|Charge with ventilation          | EV requests "Charging with ventilation" and "Charging with ventilation" is not enabled on EVSE | Enable "Allow charging with ventilation" if charged EV is located in ventilated area. |  
-|PS reading error                 | No communication with internal power sensor. |Please contact the service department of your EVSE supplier.| 
-|Current is higher than allowed   | Vehicle draws more power than allowed. |Please try to charge another EV, if error still appears, please contact the service department of your EVSE supplier. Otherwise, please contact an authorized car service department.| 
-|Internal temperature is too high | Temperature inside of charger is too high. |Make sure charger is not exposed to direct sunlight. Please contact charging station installer.|  
-</WRAP> 
- 
-====== HEMS v2.0.1 Configurator ====== 
- 
- 
-===== home ===== 
- 
-Basic system overview. 
- 
-<WRAP column 650px> 
- 
-{{  :hiq_energy:robotina_charger:hems_config_home.png?direct&800|}}  
- 
-</WRAP> 
- 
-<WRAP column 650px> 
- 
-|< 100% 120px 100px>| 
-^ 1. Grid                                                                                                             ||| 
-|  **›**                | From grid  | Tariff (LO, HI, D-LO, D-HI) and power from grid in W                             | 
-|  :::                  | :::        | Imported energy by tariff in Wh                                                  | 
-|  **‹**                | To grid    | Power exported to grid in W                                                      | 
-|  :::                  | :::        | Exported energy in Wh                                                            | 
-^ 2. Plants                                                                                                           ||| 
-|  **‹**                | Produced   | Produced power in W and energy in Wh                                             | 
-|  **›**                | Consumed   | Consumed power in W and energy in Wh                                             | 
-^ 3. Storage systems                                                                                                  ||| 
-|  **‹**                | Sourced    | Power in W and energy in Wh sourced from storage (battery)                       | 
-|  **›**                | Stored     | Power in W and energy in Wh stored (to battery)                                  | 
-|  **bargraph and %**¹  | SOC        | Battery State Of Charge                                                          | 
-^ 4. Consumers                                                                                                        ||| 
-|  **›**                | Consumed   | Consumed power in W and energy in Wh                                             | 
-|  **[]**               | Status     | Output status for managed consumers                                              | 
-|  **click**            | Toggle     | Click in frame toggles managed consumers output                                  | 
-^ 5. Unknown source                                                                                                   ||| 
-|  **›**                | Sourced    | Power in W and energy in Wh from unknown source                                  | 
-|   :!: Accumulate also all differences caused by power sensor inaccuracy                                             |||  
-^ 6. Other consumers                                                                                                  ||| 
-|  **›**                | Consumed   | Consumed power in W and energy in Wh by other (not measured) consumers           | 
-^ 7. Page navigation                                                                                                  ||| 
-|                       | home    | Home screen                                                                            | 
-|                       | power [W] | Power screen                                                                       | 
-|                       | energy [Wh]| Energy screen                                                                    | 
-|                       | timetable | Timetable screen                                                                   | 
-|                       | tariff   | Tariff screen                                                                         | 
-|                       | limiter  | Limiterscreen                                                                        | 
-|                       | ev fleet  | EV fleet screen                                                                     | 
-|                       | IO mux   | IO mux screen                                                                     | 
-|                       | settings  | Settings screen                                                                     | 
-^ 8. Exit                                                                                                             ||| 
-|                       | exit    | Close appliction                                                                        | 
- 
-¹ only for eStore 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-<WRAP pagebreak></WRAP> 
- 
-===== power ===== 
- 
-Overview of current power distribution by source / consumer. 
- 
-<WRAP column 650px> 
- 
-{{hiq_energy:robotina_charger:hems_config_power_1.png?direct&800|}} 
- 
-</WRAP> 
- 
-<WRAP column 650px> 
- 
-|< 100%>| 
-^ 1. Sourced power                                                   | 
-| Sourced power for each source                                      | 
-| Sums per source type                                               | 
-| Total of all sourced power                                         | 
-^ 2. Consumed power                                                  | 
-| Power for each consumer                                            | 
-^ 3. Power distribution                                              | 
-| Partial distributed power                                          | 
-^ 4. Submeter (Green outline)                                         | 
-| Power meter is not part of internal circuit                        | 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-<WRAP column 650px> 
- 
-{{hiq_energy:robotina_charger:hems_config_power_2.png?direct&800|}} 
- 
-</WRAP> 
- 
-<WRAP column 650px> 
- 
-|< 100%>| 
-^ 1. Sourced power distribution                                      | 
-| How sourced power is consumed by each consumer                     | 
-^ 2. Consumed power distribution                                     | 
-| Who sources consumed power                                         | 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-<WRAP pagebreak></WRAP> 
- 
-===== energy ===== 
- 
-Energy overview of a given time distributed by sources / consumers. 
- 
-<WRAP column 650px> 
- 
-{{:hiq_energy:robotina_charger:hems_config_energy.png?direct&800|}} 
- 
-</WRAP> 
- 
-<WRAP column 650px> 
- 
-|< 100%>| 
-^ 1. Sourced energy                                                  | 
-| Sourced energy for each source                                     | 
-| Sums per source type                                               | 
-| Total of all sourced energy                                        | 
-^ 2. Consumed energy                                                 | 
-| Energy for each consumer                                           | 
-^ 3. Energy distribution                                             | 
-| Partial distributed energy                                         | 
-^ 4. Submeter (Green outline)                                         | 
-| Power meter is not part of internal circuit                        | 
-^ 5. Energy since                                                    | 
-| Date and time since energy is recorded                             | 
-^ 6. Reset all                                                       | 
-| Long-press to reset all energy counters                            | 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-<WRAP pagebreak></WRAP> 
- 
-===== timetable ===== 
- 
-Weekly timetable for managed consumers. 
- 
-<WRAP column 650px> 
- 
-{{hiq_energy:robotina_charger:hems_config_timetable.png?direct&800|}} 
- 
-</WRAP> 
- 
-<WRAP column 650px> 
- 
-|< 100%>| 
-^ 1. Managed load menu                                               | 
-| Switch between managed loads                                       | 
-^ 2. Enable checkbox                                                 | 
-| When un-checked timetable is not executed                          | 
-^ 3. Events grid                                                     | 
-| Events displayed in weekly grid (15 min resolution)                | 
-| Click to select time and set event by clicking buttons below       | 
-^ 4. Once actions (top priority timetable actions)                   | 
-| Actions are executed and then automatically cleared.               | 
-| "Disable" action will just disable recurring action.               | 
-^ 5. Recurring actions (low priority actions)                        | 
-| Actions are executed each week.                                    | 
-^ 6. Cloud optimization                                              | 
-| When enabled (checked) cloud optimization is enabled.              | 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-<WRAP pagebreak></WRAP> 
- 
-===== tariff ===== 
- 
-Weekly tariff timetable for grid energy per tariff distribution. 
- 
-<WRAP column 650px> 
- 
-{{hiq_energy:robotina_charger:hems_config_tarriff.png?direct&800|}} 
- 
-</WRAP> 
- 
-<WRAP column 650px> 
- 
-|< 100%>| 
-^ 1. Tariff grid                                                                     | 
-| Graphical weekly timetable with tariffs.                                           | 
-| Click to select term, click-and-drag to select multiple terms.                     | 
-^ 2. Low tariff dates                                                                | 
-| Set low tariff dates for holidays.                                                 | 
-^ 3. Low tariff                                                                      | 
-| Set low tariff for selected terms.                                                 | 
-^ 4. High tariff                                                                     | 
-| Set high tariff for selected terms.                                                | 
- 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-<WRAP pagebreak></WRAP> 
- 
-===== lo tariff dates ===== 
- 
-Holiday dates when tariff is low 
- 
-<WRAP column 650px> 
- 
-{{hiq_energy:robotina_charger:hems_config_set_tarriff.png?direct&300|}} 
- 
-</WRAP> 
- 
-<WRAP column 650px> 
- 
-|< 100%>| 
-^ 1. Date table                                                                      | 
-| Up to 24 days when tariff is low on holiday                                        | 
-^ 2. Use easter mondays                                                              | 
-| Use preprogrammed roman-catholic easter monday holidays                            | 
- 
-</WRAP> 
- 
-<WRAP pagebreak></WRAP> 
-===== limiter ===== 
- 
-Overview and configuration of limiter 
- 
-<WRAP column 650px> 
- 
-{{hiq_energy:robotina_charger:hems_config_limiter.png?direct&800|}} 
- 
-</WRAP> 
- 
-<WRAP column 650px> 
- 
-|< 100% 30% 70%>| 
-^ 1. Grid Current limit                                                                 ||| 
-| MAX current limit                      | Current limit threshold for main grid fuse    || 
-| Enable cluster slave connection        | Current limit threshold if charger lost connection with master ||  
-| Enable limiting from cloud             | Current limit threshold if charger lost connection with cloud  ||  
-^ 2. Consumer management                                                              ||| 
-| Turn consumers on or off                                                            ||| 
-^ 3. Power                                                                            ||| 
-| Total power and power for each phase                                                ||| 
-^ 4. Current                                                                          ||| 
-| Current for each phase                                                              ||| 
-^ 5. Voltage                                                                          ||| 
-| Voltage for each phase                                                              ||| 
-^ 6. Phase order                                                                      ||| 
-| First set correct phase order for grid power sensor and then set for other power sensors/devices. **NOTE:** changing grid phase order will NOT apply to phase order of other connected devices!       ||| 
-^ 7. Status and priority                                                              ||| 
-| {{hiq_energy:hems_v1_2_0:limiter_active.png?direct&20|}} {{hiq_energy:hems_v1_2_0:limiter_inactive.png?direct&20|}} | Yellow status when limiter is enabled and active. Green status when enabled and not active   || 
-| Priority | Device priority group (no limiter, limit last, limit second, limit first) || 
-^ 8. Grid frequency                                                                   ||| 
-| Grid frequency measured on grid power meter sensor                                  ||| 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-===== ev fleet ===== 
- 
-Overview and configuration of EVSE station. Up to 7 external EVSE supported. 
- 
-<WRAP column 650px> 
- 
-{{hiq_energy:robotina_charger:hems_config_ev_fleet.png?direct&800|}} 
- 
-</WRAP> 
- 
-<WRAP column 650px> 
- 
-|< 100% 30% 70%>| 
-^ 1. EVSE - Robotina Charger                                                                 ||| 
-| [[en:robotina_charger:software#evse_overview|Robotina charger]] ||| 
-^ 2. Other EVSE (charging station) linked to Robotina charger                                                                ||| 
-| EVSE could have up to 7 charging stations directly connected and related settings are as above. ||| 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-===== io mux ===== 
- 
-Overview and configuration of input/output ports IO mux 
- 
-<WRAP column 650px> 
- 
-{{hiq_energy:robotina_charger:HEMS_config_io_mux.png?direct&800|}} 
- 
-</WRAP> 
- 
-<WRAP column 650px> 
- 
-|< 100%>| 
-^ 1. Wireless relay WR-1 output function                                                ||| 
-| On left side are WR-1 modules [[en:hiq_hw:wr-1|WR-1]] (max 8) with corresponding status (active + communication status). To each WR-1 could be assigned HEMS function (e.g. digital, linker reset, router reset, heat pump channel etc) with output mode (normal or inverted).  ||| 
-^ 2. HEMS input and output function (wired connection) - not for EVSE available                           ||| 
-| On the left side are MC controller ([[en:hiq_hw:mc-230|MC-230]]) ports to which could be assigned MC-230 functions (digital, linker reset, router reset, etc) with output mode (normal or inverted). ||| 
-| Default settings are for e.g. QX0 -> digital 1 while digital 1 is defined for consumer 1  on settings page. Change to define new function role to QX0 port e.g. for linker reset ||| 
-| Enable consumer at input IX0,IX1 or IX2 means that dedicated consumer will be managed (ON/OFF) by input signal on IX0,IX1 or IX2. For example, if thermostat signal is wired to IXO port and "Enable consumer 1" to IX0, while thermostat is active, consumer 1 is active and otherwise. ||| 
-| Limitations: one temperature sensor is allowed, one consumer could be managed by one input only. ||| 
-^ 3. Heat pump supported operation mode                               ||| 
-| To control Heat pump by EVSE, define supported operation(control) mode based on heat pump specification. E.g. SGRHP supports external control by two channels (Off, Normal, Increased and Increased + additional heater) thus select them in table to enable functionality.\\ **Note**: Before selecting modes, heat pump must be defined in setting page!||| 
-^ 4. Slave device IP address                           ||| 
-| For device (PV inverter or external EVSE) define its IP address.  ||| 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
-<WRAP pagebreak></WRAP> 
- 
-===== settings ===== 
-<WRAP column 650px> 
-{{:hiq_energy:robotina_charger:hems_config_settings.png?direct&800|}} 
-</WRAP> 
- 
-<WRAP column 650px> 
- 
-|< 100% 100px 100px>| 
-^ 1. System settings                                                                                                                                                            ||| 
-|  **[autodetect]**                   || Click to find EVSE in local network.                                                                                                        | 
-|  **eStore**          | c.....     | eStore serial number (automatically detected or can be entered manually).                                                                   | 
-| :::                  | [] enable  | When selected EVSE will obtain necessary data (power, voltage...) directly from battery storage system, no need to additional power sensor. | 
-| :::                  | [detect]   | eStore address is cleared and new eStore can be detected.                                                                                   | 
-|  **HIQ Home**            | c.....     | HIQ Home serial number (automatically detected or can be entered manually).                                                                 | 
-| :::                  | [] enable  | When checked HEMS will read Grid power and energy from HIQ Home (so there is no need to duplicate power-sensor).                            | 
-| :::                  | [detect]   | HIQ Home address is cleared so new can be detected.                                                                                         | 
-|  **Virtual grid PS**     | [] enable  | Select if system is without main grid power meter. Energy, power and currents are calculated from other power meters.                       | 
-|  **Internal temperature**  | Temperature inside of EVSE                                                                                                                            || 
-|  **Modbus (wired) cycle time**       | Cumulative reading time of all wired power sensor in ms                                                                                     || 
-|  **Modbus (wireless) cycle time**    | Cumulative reading time of all wireless connected power sensor in ms                                                                        || 
-|  **Modbus (TCP) cycle time**         | Cumulative reading time of all TCP connected devices in ms                                                                                  || 
-|  **IP address**         | IP address of EVSE  || 
-|  **DHCP**          | Select for DHCP to obtain an IP address automatically -> apply and save to confirm.  || 
-|  **Static IP**     | Set static IP to EVSE -> apply and save to confirm.      || 
-|**Note:** If IP settings are failed, restart EVSE with jumper between IX1-GND to DHCP  ||| 
-^ 2. Sources and Consumers settings table                                                                                                                                           ||| 
-|      **SOURCES**             | Source name                                                                                                                                         || 
-|      **icon**                | Source icon                                                                                                                                         ||  
-^ 3. Device status                                                                                                                                                                  ||| 
-|      **Status**              | Status OK, Warning, Error, Detected                                                                                                                 || 
-^ 4. Device message                                                                                                                                                                 |||                                                                                                                                        
-|  **source and consumer management**       | Source or consumer power sensor management                                                                                             || 
-|  :::                        |   message  | Messages related to source or consumer power sensor                                                                                      | 
-^ 5. Device configuration                                                                                                                                                           |||          
-|   **Configuration**          |   add      | Associate new power sensor to source or consumer                                                                                        | 
-|   :::                        |   del      | Disassociate power sensor from source or consumer & configure it as new power-sensor                                                    | 
-^ 6. Device type                                                                                                                                                                    ||| 
-|      **meter**               | Source or consumer power-sensor type                                                                                                                || 
-|      **configuration**        in/ex     | Power plant connection¹                                                                                                                 | 
-^ 7. Submeter option                                                                                                                                                                ||| 
-|      **sub**                 | Check if this power meter or device is not part of internal circuit. Energy division for this device is ignored and outlined in green color.        || 
-^ 8. New device                                                                                                                                                                     ||| 
-|Detected new power sensor.                                                                                                                                                         ||| 
-^ 9. Device output                                                                                                                                                                  |||                                                                             
-|      **output**              | Select consumer output type                                                                                                                         || 
-|    **man. time**             | Managed consumer manual override timer                                                                                                              || 
-|    **P nominal**             | Enter power for device in case where power sensor is not assigned to device.                                                                        || 
-|    **clock**                 | Enable timetable  || 
-^ 10. Permanent memory parameters                                                                                                                                                ||| 
-|  **[init parameters]**       | Init all parameters to default values                                                                                                                || 
-|  **[save parameters]**       | Save all parameters to permanent memory                                                                                                             || 
-|  **[read parameters]**       | Read all parameters from permanent memory                                                                                                           || 
-|  **[] autosave parameters**  | Parameters will be automatically saved to permanent memory in 15 minutes after last parameter change                                                || 
-^ 11. WM / WR settings                                                                                                                                                     ||| 
-|  **Scan w-less dev.**       | Press to start scanning for power sensors wirelessly connected via [[en:hiq_hw:wm-1|WM-1]] module as well as for [[en:hiq_hw:wr-1|WR-1]] relay. Scanning is active for 5 minutes.  || 
-|  **WM / WR binding**        | Press to add new WM-1 or/and WR-1 to existing group or to create new New group of wireless modules                                                                     || 
-^ 12. Backup / Restore to PC                                                                                                                                                     ||| 
-|  **[backup]**                | Backup all parameters to PC                                                                                                                         || 
-|  **[restore]**               | Restore all parameters from PC backup<sup>2</sup>                                                                                                               || 
- 
-<sup>1</sup> only for the first power plant 
- 
-<sup>2</sup> older versions of backup files may be used. Any unsuccessfully backup or restored parameters will be displayed but operation will end successfully if you use **continue**.   
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
- 
- 
- 
  