====== Single phase power-sensor ====== **Single phase power-sensor** {{ :hiq_energy:hems:hardware:pm1-e-d.png?nolink |}} | Model number: ^ PM1-E-D | | Connect to: | [[en:hiq_hw:mc-230|MC-230]] | | ::: | RS485 power sensor bus A - B | | Mounting: | DIN rail, 1M, 18 mm | | Dimensions: | 18 × 62 × 119 mm | ^ Used for measuring power and energy of || | ✔ | single-phase energy sources | | ✔ | single-phase energy consumers | ===== Applications ===== * Digital multi-function power-sensor for single phase networks ===== Features ===== * DIN rail mounting with direct connection up to 45A * Compact design in a single module 18mm wide * Seal-able cover(phase and neutral terminals) ===== General description ===== The PM1-E-D series is an advanced single phase energy monitoring solution with built-in configuration push button and LCD data display. Particularly indicated for metering active energy and other power parameters. Housing for DIN-rail mounting, IP51 protection degree, direct connection up to max 45A. ===== Technical specifications ===== |< 40% 50% >| ^ Energy Measurements || | Imported/Exported active energy | 0 to 99999.99 kWh | | Imported/Exported reactive energy | 0 to 99999.99 kVArh | | Total active energy | 0 to 99999.99 kWh | | Total reactive energy | 0 to 99999.99 kVArh | ^ Measured Inputs || | Nominal Voltage Input | (Ph+N) 176 to 276V | | Max Continuous Voltage | 120% of nominal | | Nominal Input Current | 5(45)A | | Max Continuous Current | 120% of nominal | | Frequency | 50Hz (±10%) | ^ Accuracy || | Voltage | 0·5% of range maximum | | Current | 0·5% of nominal | | Frequency | 0·2% of mid-frequency | | Power factor | 1% of unity (0.01) | | Active power (W) | ±1% of range maximum | | Reactive power (VAr) | ±1% of range maximum | | Apparent power (VA) | ±1% of range maximum | | Active energy (Wh) | Class 1 IEC 62053-21 | | Reactive energy (VARh) | ±1% of range maximum | ^ Modbus (RS485 Output for Modbus RTU & Pulsed Output) || | Baud rate | 1200, 2400, 4800, 9600. | | Parity | none / odd / even | | Stop bits | 1 or 2 | | RS485 network address | 1 to 247 | ^ Reference Conditions of Influence Quantities || | Ambient temperature | 23°C ±1°C | | Input waveform | 50 or 60Hz ±2% | | Input waveform | Sinusoidal (distortion factor < 0·005) | | Auxiliary supply voltage | Nominal ±1% | | Auxiliary supply frequency | Nominal ±1% | | Auxiliary supply waveform (if AC) | Sinusoidal (distortion factor < 0·05) | | Magnetic field of external origin | Terrestrial flux | ^ Environment || | Operating temperature | -25°C to +55°C | | Storage temperature | -40°C to +70°C | | Relative humidity | 0 to 95%, non-condensing | | Altitude | Up to 3000m | | Warm up time | 1 minute | | Vibration | 10Hz to 50Hz, IEC 60068-2-6, 2g | | Shock | 30g in 3 planes | ^ Mechanics || | DIN rail dimensions | 18mm x 90mm (WxH) per DIN 43880 | | Mounting | DIN rail (DIN 43880) | ===== PM1-E-D Wiring ===== {{:hiq_energy:hems:hardware:pm1_terminals.png?nolink|}} {{ :hiq_energy:hems:hardware:HIQ PM1-E-D user manual 2020.pdf |}} {{ :hiq_energy:hems:hardware:HIQ PM1-E-D-Modbus protocol V2.2.pdf |}}