Commissioning

Mounting

Mount the main controller MC-230, PM1-E-D, PM3-E-D and PM3-I-D electricity sensors, fuses, power relays, and push-buttons to a suitable location.

Wiring

Wire all elements except communication with PM1-E-D and PM3-E-D sensors.

Connect the MC-230 to the home LAN.

Configuration

Install and run HEMS Configurator on your PC.

Go to the “settings” page.

With the “autodetect” button, the application will locate the controller in the local network.

Enter names, select icons for all sources and consumers.

Power-sensor adding

One-phase sensor PM1-E-D

Three-phase sensor PM3-E-D

Three-phase sensor PM3-I-D

Power-sensor removing

One-phase sensors PM1-E-D

Three-phase power-sensor

Power plant connection¹

The power plant can be connected to the grid in two ways:

serial with grid power sensor parallel with grid power sensor

When configuring the power plant, select

In HEMS Configurator by default, the power plant is connected in series.

Wireless setting

Enable the wireless setting to add, delete, or set repeater level wireless modules.

Wireless module adding

Temperature and humidity sensor
Micro smart plug and Smart plug
Relay switch-1 channel
Relay switch-2 channel

Wireless module removing

Micro smart plug, smart plug and relay switch-1 channel
Relay switch-2 channel

Setting repeater level

When enabling repeater mode, the wireless module can repeat a message not addressed to him, and increase range by creating network grid between all wireless devices.

The repeater can be configured to level 0 (off), level 1 (one hop), or level 2 (two hops):

By default, the repeater mode is disabled (level 0). If you want to change the repeater mode press icon «» in the output in Consumers settings table.

Setting device management features

For each managed consumer we can set:

Enable power-sensor from compatible systems

HEMS will automatically detect compatible

which are in the same local network.

Only the first system is detected, if there is more than one it is necessary to enter the serial number of the desired system manually.

if eStore is enabled, HEMS will read:

From the enabled HIQ Home system, HEMS will automatically read the grid power-sensor.

Internet access

If enabled, the system will automatically establish access to the HIQ Universe web service. Communication with the server is automatically established so that the controller sends the push message to the server, and the server can then access the controller on the given path. The UDP type of internet packets on the output port 8442 is used. If communication is not established automatically, check the access from the local network to the Internet and the router settings.

Permanent memory

Saving parameters to the permanent memory, after changing the settings, is necessary since at startup HEMS always reads parameters from the permanent memory.

Backup / restore to PC

HEMS Configurator allows you to backup and restores all parameters to PC.

¹ Only for the first power plant

² Both repeaters must be set to level 2