Table of Contents

Commissioning

Strictly follow Safety instructions!

Mounting

Mount the main controller MC-230, IOT-L2-2 linker, PM1-E-D, PM3-E-D and PM3-I-D power sensors, fuses, power relays, and push-buttons to a suitable location.

Wiring

Wire all elements except communication with PM1-E-D and PM3-E-D sensors.

Connect the MC-230 and IOT-L2-2 to the home LAN or use LTE 4G modem.

Configuration

Install and run HEMS Configurator on your PC.

Go to the “settings” page.

With the “autodetect” button, the application will locate the controller in the local network.

Enter names, select icons for all sources and consumers.

Power-sensor adding

Note: adding is supported one by one.

One-phase sensor PM1-E-D

Three-phase sensor PM3-E-D

Three-phase sensor PM3-I-D

Without grid power sensor

Power-sensor removing

One-phase sensors PM1-E-D

Three-phase power-sensor

Power plant connection

The power plants can be connected to the grid in two ways:

serial with grid power sensor parallel with grid power sensor

When configuring the power plant, select

The power plants are configured as internal by default.

Wireless setting

Enable the wireless setting to add, delete, or set repeater level of wireless modules.

Wireless module adding

Temperature and humidity sensor
Micro smart plug and Smart plug
Relay switch-1 channel
Relay switch-2 channel

Wireless module removing

Micro smart plug, smart plug and relay switch-1 channel
Relay switch-2 channel

Setting repeater level

When enabling repeater mode, the wireless module can repeat a message not addressed to him, and increase range by creating network between all wireless devices.

The repeater can be configured to level 0 (off), level 1 (one hop), or level 2 (two hops):

By default, the repeater mode is disabled (level 0). If you want to change the repeater mode press icon «» in the output in Consumers settings table.

¹ Both repeaters must be set to level 2.

Setting device management features

For each consumer we can set:

Enable power-sensor from compatible systems

HEMS will automatically detect compatible

which are in the same local network.

Only the first system is detected, if there is more than one it is necessary to enter the NAD number of the desired system manually.

if eStore is enabled, HEMS will read:

From the enabled HIQ Home system, HEMS will automatically read the grid power-sensor.

Internet access

HEMS is connected to the internet via IOT-L2-2 linker.

Digital output

HEMS is supporting up to 8 digital outputs on MC controller (QX0,QX1,QX2,QX3,IO12,IO13,IO14 and IO15). How to set?

Note: if it is set digital for consumer without assigned power sensor, it is possible to define P nominal power instead. It represents fixed power of consumer and while in operating mode HEMS calculates consumed energy.

Analog output

On port IO14 is supported analog output 0-10V, while on IO15 is PWM signal with frequency of 1kHz. Using analog load is possible for consumer 1 only! How to set (HEMS wiring)?

Note: if it is set analog for consumer without assigned power sensor, it is possible to define P nominal power instead. It represents fixed power of consumer and while in operating mode HEMS calculates consumed energy.

IO mux

IO mux page within HEMS configurator allows setting of input/output types for ports on controller:

Permanent memory

Saving parameters to the permanent memory, after changing the settings, is necessary since at startup HEMS always reads parameters from the permanent memory.

Backup / restore to PC

HEMS Configurator allows you to backup and restores all parameters to PC.

Phase alignment and limiter settings

Under limiter page set correct phase order to align phases of each device. Set correct main fuse limit [A] to protect the main grid fuse from over current. Check devices that can be managed by limiter and set correct limiter priority. Choose from no limiter, limit last, limit second, limit first. Max expected device current consumption is dynamically calculated and does not need to be set. In case device is an EV charging station, manually set max current for this device.