en:robotina_charger:commissioning:power_sensor
This is an old revision of the document!
Add power sensor
Default address on all power sensor is 149.
Available addresses for sensors are listed in table.
Note: adding is supported one by one.
Address | Power sensor position |
---|---|
150 | Grid |
154,155,156 | PV |
157,158 | Battery storage |
161..167 | Consumer |
One-phase sensor PM1-E-D
- Wire it to communication bus,
- press and hold the push-button on the power sensor until it appears -SEt- on display,
- it should appear in configurator as new device, click on button add next to the source or consumer where sensor should be assigned,
- repeat procedure for next PM1-E-D.
Three-phase sensor PM3-E-D
It is possible to set address manually according to table above before adding it to communication bus or
- Connect communication bus (to only one power-sensor)
- In HEMS Configurator power-sensor should appear as a “new device”
- Click on the “ add” button next to the source or consumer that the sensor is measuring
- Connect communication bus to the next power-sensor and repeat procedure
Note: .Allowed addresses are 150,154,161-167.
Without grid power sensor
- Virtual grid PS is an option if no grid meter is used. Power, current and energy will be calculated from other power sensors.
Power-sensor removing
One-phase sensors PM1-E-D
- Make sure the “new device” is empty
- Press the button on power-sensor until -Set- appears on the display
- In HEMS Configurator press “del” button next to the sensor
- After a few seconds, the sensor should appear as the “new device”
- If desired, the sensor can be removed or it can be assigned to another device
Three-phase power-sensor
- Make sure the “new device” is empty
- In HEMS Configurator press “del” button next to the sensor
- After a few seconds, the sensor should appear as the “new device”
- If desired, the sensor can be removed or it can be assigned to another device