-====== Hotel room extension ====== 
- 
-**Hotel room lights and blinds controller ** 
- 
-<WRAP column 350px> 
- 
-{{  hiq_building_automation:hiq_hotel:hw:hr-ext.png?nolink  }} 
- 
-</WRAP> 
- 
-<WRAP column 300px> 
- 
-| Model number: ^   HR-EXT            | 
-| Mounting:     | DIN rail, 6M, 106mm | 
-| Dimensions:   | 106x108x58mm        | 
- 
-===== Applications ===== 
- 
-  * Hotel room lights controller 
-  * Hotel room blinds controller 
-  * Hotel room bathroom fan controller 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-===== Features ===== 
- 
-  * Configurable welcome and goodby scene 
-  * Advanced master light control (night mode) 
-  * Easy push-button control 
-  * Periodic / controlled bathroom ventilation when room is inactive, occupied or free 
- 
-===== General description ===== 
- 
-**Hotel room extension** if expansion for Hotel room controller which allows to completely control all hotel room lights, bathroom fan and blinds. 
-  
-===== Technical specification ===== 
- 
-| Output power per relay                |                              | 
-| - incandescent / halogen 230V         |                         800 W| 
-| - halogen 12 V with transformer       |                         400 W| 
-| - fluorescent with electronic ballast |                         400 W| 
-| - parallel compensated fluo lamps     |                 250 W / 30 uF| 
-| Total output power (all relays):      |                        4000 W| 
-| Inputs                                |  internal pull-up, 12 V, 2 mA| 
-| Maximum input cable length:           |                          50 m| 
-| Power supply:                         |                 24 V / 120 mA| 
-| Ingress protection:                   |                          IP20| 
-| Operating temperature:                |                      0..45 °C| 
-| Storage temperature:                  |                    -20..75 °C| 
-| Relative humidity:                    |                   0..95 % n/c| 
- 
-===== Terminals ===== 
- 
-| Lights power supply ^  L  ^   1   | Relay outputs common |   | Power supply         ^  19   ^ 24V | +24 VDC power supply        | 
-| :::                 ^  L  ^   2   | :::                  |:::| :::                  ^  20   ^  0V | 0 VDC power supply          | 
-|                     ^     ^   3   |                      |:::|                      ^  21   ^     |                             | 
-| Light 0 live        ^ QX0 ^   4   | Relay output 0       |:::| Digital input 0      ^  22   ^ IX0 | Light 0 push-button         | 
-|                     ^     ^   5   |                      |:::|                      ^  23   ^     |                             | 
-| Light 1 live        ^ QX1 ^   6   | Relay output 1       |:::| Digital input 1      ^  24   ^ IX1 | Light 1 push-button         | 
-| Light 2 live        ^ QX2 ^   7   | Relay output 2       |:::| Digital input 2      ^  25   ^ IX2 | Light 2 push-button         | 
-|                     ^     ^   8   |                      |:::|                      ^  26   ^     |                             | 
-| Light 3 live        ^ QX3 ^   9   | Relay output 3       |:::| Digital input 3      ^  27   ^ IX3 | Light 3 push-button         | 
-|                                                       ||||:::|                                    |                           ||| 
-| Light 4 live        ^ QX4 ^  10   | Relay output 4       |:::| Digital input 4      ^  28   ^ IX4 | Light 4 push-button         | 
-|                     ^     ^  11   |                      |:::|                      ^  29   ^     |                             | 
-| Light 5 live        ^ QX5 ^  12   | Relay output 5       |:::| Digital input 5      ^  30   ^ IX5 | Light 5 push-button         | 
-| Light 6 live        ^ QX6 ^  13   | Relay output 6       |:::| Digital input 6      ^  31   ^ IX6 | Light 6 push-button         | 
-|                     ^     ^  14   |                      |:::|                      ^  32   ^     |                             | 
-| Bath fan            ^ QX7 ^  15   | Relay output 7       |:::| Digital input 7      ^  33   ^ IX7 | Bath fan push-button        | 
-| Blinds 0 up         ^ QX8 ^  16   | Relay output 8       |:::| Digital input 8      ^  34   ^ IX8 | Blinds 0 up push-button     | 
-|                     ^     ^  17   |                      |:::|                      ^  35   ^     |                             | 
-| Blinds 0 down       ^ QX9 ^  18   | Relay output 9       |:::| Digital input 9      ^  36   ^ IX9 | Blinds 0 down push-button   | 
- 
- 
  