User Tools

Site Tools


en:goflex_hems:methods_resources:wiring

GOFLEX HEMS wiring

Control distribution-board wiring

Control system and Communication interfaces wiring

PS-IQ DIN rail
L, N to 230 VAC power supply
+, - to HC-IQ 24V, 0V (1, 2)
+, - to GW-WN-W +, -
HC-IQ DIN rail
24V (1), 0V (2) to PS-IQ +, -
C0 (4), C1 (10) Power relays supply
QX0-QX7 (5-9, 11-13) Managed loads power relays
24V (19) to HC-IQ C3 (22)
0V (20) to push-buttons common
IX1-IX7 (23-29) to push-button
RJ10 (right side) to next DIN rail module
CAD-232-A2-IQ DIN rail
A (1), B (2), C (3) RS485 bus to power-meters and to GW-WN-IQ
RJ10 (left side) to previous DIN rail module
RJ10 (right side) to next DIN rail module
CAD-BE-PROT-IQ DIN rail
GND (1), CANL (2), CANH (3), +24V (4) IEX2 bus to field modules
RJ10 (left side) to previous DIN rail module
RJ10 (right side) to next DIN rail module
AIR-12-IQ DIN rail
IWx , C Pt 1000 temperature probe
RJ10 (left side) to previous DIN rail module
RJ10 (right side) to next DIN rail module
GW-ENO-IQ DIN rail
RJ10 (left side) to previous DIN rail module
RJ10 (right side) to next DIN rail module
GW-WN-W on wall
+, - to PS-IQ +, -
Rx/T+, Tx/T- to CAD-232-A2-IQ A, B
DIP settings 1=ON, 2-8=OFF

Power meters

Sources and consumers measurements

PM3-I-D DIN rail
L1i, L2i, L3i, N to power source L1, L2, L3, N (grid, local power plant, generator, …)
L1o, L2o, L3o, N to consumers L1, L2, L3, N
15, 16 to CAD-232-A2-IQ A,B or to BR-WN-W Rx/T+, Tx/T- when there is no possibility to connect directly
PM1-E-D DIN rail
L↑ (1) to power source L (grid, local power plant, generator, …)
L↓ (2) to consumer L
9, 10 to CAD-232-A2-IQ B,A or to BR-WN-W Tx/T-, Rx/T+ when there is no possibility to connect directly
BR-WN-W on wall
+, - to Plug-in power supply +, - (included in the delivery)
Rx/T+, Tx/T- to PM1-E-D 10, 9 ot to PM3-I-D 15,16
DIP settings ALL OFF

Load managers

Power-relays DIN rail
Relays control voltage A1, A2 HC-IQ-HEMS QX0-QX7 for managed load 1 to 8, N
(2, 4 or 2, 4, 6, R8) Consumer power supply L, N or L1, L2, L3, N
(1, 3 or 1, 3, 5, R7) Consumer L, N or L1, L2, L3, N
PM1-WN-D DIN rail
16, 17 power supply 230 VAC
2, 3 current transformer black, red
6, 7 consumer power supply - consumer L
PM1-WN-W on wall
1, 1a PE, internally connected
2, 2a N, internally connected
3 Device supply / Current transformer black
3a Current transformer red
3b Output (Consumer)
RL1-WN-W on wall
1, 1a PE, internally connected
2, 2a N, internally connected
3 Device and consumer supply
3a Consumer output
SC1-WN-F power outlet
Plugged in power outlet, consumer plugged in

Control devices

Push-buttons in wall
Common HC-IQ-HEMS 0 V (20)
Signal (NO) HC-IQ-HEMS IX0-IX7 (21)-(29)

Sensors

TS-H on wall
GND, CANL, CANH, +24V BE-PROT-IQ GND, CANL, CANH, +24V
TS0, GND ES external temperature probe red, black
AIR-12 DIN rail
C, IW0-IW11 Pt1000 temperature probes
RJ10 (left side) to previous DIN rail module
RJ10 (right side) to next DIN rail module
TDI-WN-W on wall
1, 2 (from top) Digital input 1
3, 4 Digital input 2
5, 6 NTC temperature probe input 1
7, 8 NTC temperature probe input 2
+, - Plug-in power supply
DIP setting Address setting: [1=lsb, 8=msb]
- sensor 1, address 60 = 0011 1100
- sensor 2, address 61 = 1011 1100
- sensor 3, address 62 = 0111 1100
- sensor 4, address 63 = 1111 1100
- sensor 5, address 64 = 0000 0010
- sensor 6, address 65 = 1000 0010
- sensor 7, address 66 = 0100 0010
- sensor 8, address 67 = 1100 0010
en/goflex_hems/methods_resources/wiring.txt · Last modified: 2018/10/05 13:32 by goran.kocjancic