Devices wiring
Discrete (on/off) & Dimmable lights
Individual lights (or hard-wired light groups) are wired directly to the distribution box with an appropriate wire gauge (usually 3 × 1,5 mm2).
Push-button flush boxes are wired directly to the distribution box with signal wires. One wire for each push-button and one common wire (for 3 push-buttons: 4 × 0,5 mm2). Push buttons that are controlling same light are connected to the same input in parallel.
Sensors are wired directly to distribution box. More sensors can be used for same light. Presence sensors must be wired in parallel, read sensors in series.
Light | |
---|---|
Dimmable light | |
Push-button | |
Door / window reed sensor | |
PIR motion sensor | |
Light sensor |
DALI dimmable lights
All light ballasts are wired to DALI bus with an appropriate wire gauge (usually 5 × 1,5 mm2)
Push-button flush boxes are wired directly to the distribution box with signal wires. One wire for each push-button and one common wire (for 3 push-buttons: 4 × 0,5 mm2)
Sensors are wired directly to the distribution box. More sensors can be used for the same light. Presence sensors must be wired in parallel, read sensors in series.
DALI Light |
---|
Individually managed sockets
Individual sockets are wired directly to the distribution box with an appropriate wire gauge (usually 3 × 2,5 mm2)
Push-button flush boxes are wired directly to the distribution box with signal wires. One wire for each push-button and one common wire (for 3 push-buttons: 4 × 0,5 mm2)
Group managed sockets
Sockets group is wired to the distribution box with an appropriate wire gauge (usually 3 × 2,5 mm2)
Push-button flush boxes are wired directly to the distribution box with signal wires. One wire for each push-button and one common wire (for 3 push-buttons: 4 × 0,5 mm2)
Blinds motors
Blind motors are wired directly to the distribution box with an appropriate wire gauge (usually 4 × 1,5 mm2)
Push-button flush boxes are wired directly to the distribution box with signal wires. One wire for each push-button and one common wire (for 2 push-buttons (up/down): 3 × 0,5 mm2)
Blinds motor | |
---|---|
Blinds push-buttons |
Exhaust fan
Exhaust fans are wired directly to the distribution box with an appropriate wire gauge (usually 3 × 1,5 mm2)
Push-button flush boxes are wired directly to the distribution box with signal wires. One wire for each push-button and one common wire (for 1 push-button: 2 × 0,5 mm2)
Exhaust fan motor |
---|
HVAC
Radiator valves and boiler enable signal are wired directly to the distribution box with an appropriate wire gauge (usually 3 × 1,5 mm2)
Thermostat is field module - see Field modules wiring.
Radiator valve |
---|
Field modules
Applies to:
- Light controller
- LD-V4-IQ
- Scene controllers
- SC-4T-IQ
- SC-4O-IQ
- SC-4S-IQ
- HVAC controllers
- TH-1M-IQ
- TH-1T-IQ
- TH-2-IQ
- TH-3-IQ
- HVAC actuators
- FC-1-IQ
IEX2 bus |
---|
All field modules are connected to the IEX bus with 2 x 2 x 0,8 mm2 cable.
Some devices controlled by Field modules needs additional power supply:
- LD-V4-IQ need LED power supply; 12 or 24V DC depending of LED stripe type
- FC-1-IQ need fan-coil motor and valve power supply; see fan-coil documentation - usually 230V AC
LED stripe |
---|
Fan-Coil Fan | |
---|---|
Fan-Coil Valve |