Typical installations

Small shop, pharmacy

Requirements

  • limited number of visitors
  • one passage for access and exit
  • automatic door
  • required temperature measurement
  • required disinfection

Installation

  • SGate is installed at the entrance from the outside of the automatic door.
  • Entry detection sensors are mounted on one of the sides or on an additional carrier depending on the physical layout of the SGate relative to the door..
  • The automatic door opening signal is connected to the SGate and in parallel to the internal automatic opening sensor.
  • The staff has a wireless button to confirm alarms or to open the door manually in case of exceptions.

Settings

Department store

Requirements

  • limited number of visitors
  • one-way entrance with swing gate
  • separate exit
  • required temperature measurement
  • required disinfection
  • staff can access it by scanning the code even when the count limit 1 is exceeded
  • staff do not need to scan the temperature 4 hours after a successful scan
  • hand disinfection is not mandatory for employees

Installation

  • SGate is installed at the entrance from the outside of the swing gate.
  • Entry detection sensor is mounted on side of SGate or on an additional carrier depending on the physical layout of the SGate relative to the gate.
  • Security guard has a wireless button to confirm alarms or to open the door manually in case of exceptions.

Settings

Staff code

Offices

Requirements

  • number of visitors not limited
  • one passage for access and exit
  • automatic door
  • required temperature measurement
  • employees do not need to scan the temperature 4 hours after a successful scan
  • required disinfection
  • required authentication with code for employees and guests
  • guests are exceptionally allowed to enter with confirmation of the reception (without code)

Installation

  • SGate is installed at the entrance from the outside of the automatic door.
  • Entry detection sensor is mounted on side of SGate or on an additional carrier depending on the physical layout of the SGate relative to the door.
  • Receptionist has a wireless button or PC application to confirm alarms or to open the door manually in case of exceptions.
  • Upon booking a meeting, each guest receives a QR code, which is time limited.

Settings

Employee code

Guest code

Health Center

Requirements

  • visitors can enter only at a specified time
  • one passage for access and exit
  • automatic door
  • required temperature measurement
  • required disinfection

Installation

  • SGate is installed at the entrance from the outside of the automatic door.
  • Entry detection sensors are mounted on side of SGate or on an additional carrier depending on the physical layout of the SGate relative to the door.
  • Receptionist has a wireless button to confirm alarms or to open the door manually in case of exceptions.
  • Upon booking, each visitor receives a QR code, which is time limited.

Settings